Skip to content
Get a free curing planQuote

UV-LED Curing for Optical Fiber and Lens Bonding

Quick answer

Fiber and lens bonding uses UV-LED point sources because the joint is small, the adhesive is optically clear, and cure must finish before the alignment drifts. A Ø10 mm spot at 2,000 mW/cm² sets most fiber adhesives in 5–20 seconds with minimal shrink stress.

Alignment is the whole cost of an optical assembly. Any movement during cure shows up as insertion loss, so the adhesive must set fast and shrink little. UV-cured acrylates for optics are formulated for exactly this, and they need a light source with stable, repeatable output.

Point sources reach into fixtures where a large window cannot go, and the small emitting area means stray light does not hit neighbouring fibers or the detector.

Typical processes

  • Fiber-to-ferrule and fiber-to-V-groove bonding
  • Lens and prism attachment in imaging modules
  • Fiber array and waveguide pigtailing
  • GRIN lens and collimator assembly

Questions from the line

Which wavelength for optical adhesives?

Most optical acrylates are sensitised for 365 nm, which also cures through clear substrates quickly. Use 395 nm only if the adhesive datasheet specifies it or the substrate blocks shorter wavelengths.

How do I avoid cure shrinkage shifting the alignment?

Cure at reduced intensity first (around 30%) for a few seconds to gel the adhesive, then ramp to full power. This two-step profile is standard practice in fiber alignment and is easy to program on our controllers.

Recommended systems

Ø10 mm10 mm WDAir-cooled

GUGU-P10

UV-LED Point Light Source

Ø10 mm spot, up to 2,000 mW/cm². Air-cooled head on 24 V DC, ideal for manual dispensing cells.

  • 365 / 385 / 395 / 405 nm
  • Ø10 mm
  • up to 2,000 mW/cm²

Specifications →

Free curing plan

Send the adhesive datasheet plus part size and cycle time. We reply with emitter type, wavelength and dose.

Ask an engineer