Skip to content
Get a free curing planQuote

UV-LED vs mercury lamp: what the running cost actually looks like

The purchase price favours mercury. The five-year total usually does not. Here is the arithmetic, including where mercury still wins.

The case for UV-LED is usually made with adjectives — cooler, greener, instant. The case that survives a purchasing review is made with numbers. Four of them matter: electricity, bulbs, chiller load and unplanned downtime.

Where the money actually goes

Typical comparison for a comparable cure width, mid-size production line
Cost lineMercury (medium pressure)UV-LED
Lamp electrical draw3–8 kW0.5–2 kW
Warm-up / shutter idling3–10 min per start, shutter stays hotInstant on/off, no idling
Bulb or module replacement800–2,000 h per bulb15,000–20,000 h to 70% output
Heat into the substrateHigh — infrared plus UVLow — UV only
CoolingChiller or high-volume extractionAir for small heads, water for large arrays
Consumables / disposalBulbs are hazardous waste in most marketsNone routine

The electricity line is the one buyers underestimate. A 6 kW mercury system running 4,000 hours a year at USD 0.15/kWh costs about USD 3,600 in power alone, before the chiller is counted. An LED system of the same cure width at 1.5 kW costs about USD 900. That is USD 2,700 a year, every year, on one lamp.

A payback example

Assume a line that runs one shift, 4,000 h a year, with a 200 mm cure width. Mercury system capex USD 4,000–6,000; comparable LED system USD 9,000–14,000. Add electricity savings of about USD 2,700 a year, bulb and labour savings of roughly USD 500, and avoided chiller power of a few hundred more. Payback lands between two and three years, and the LED keeps saving after that.

Three things can move that number a lot: how many hours the line actually runs (double shifts halve the payback), local electricity price, and whether the existing chiller can be removed entirely rather than just idled.

The costs that do not appear on a quote

  • Downtime. A mercury lamp needs warm-up before the first good part and a cool-down before it can be handled. Every stop-start cycle costs minutes; on a short-run high-mix line that is hours a week.
  • Scrap from heat. Thin film, foam board and heat-set substrates cockle under infrared. That scrap shows up in the quality budget, not the maintenance budget.
  • Compliance handling. Bulbs are mercury-containing waste in most jurisdictions, which means storage, transport and disposal paperwork.

Where mercury is still the right answer

An honest supplier will tell you this, so here it is. Mercury still wins when:

  • you need deep UV below 300 nm — 254 nm is common for surface sterilisation and some clear coatings, and LED equivalents are rare and expensive;
  • the coating is very thick and heavily pigmented, where broadband output and high peak power do work that a narrow LED peak struggles with;
  • the line runs a few hundred hours a year and capex dominates the decision.

If any of those apply, the honest answer is a hybrid: keep mercury where it earns its place, convert the high-volume stations where LED pays back.

Regulatory direction

Mercury-containing lamps are being phased out under the Minamata Convention, with exemptions and timelines that vary by country, and they already fall under RoHS restrictions in the EU with limited exemptions. Check the rules for your own market and for your customer’s market before specifying new equipment — a line bought in 2026 will still be running when the exemptions tighten.

What to ask for in a quote

  • Measured irradiance at the working distance, not a datasheet peak.
  • Wall-plug power for the complete system including cooling.
  • Rated hours to 70% output, and the replacement cost of the module.
  • Whether the existing chiller can be removed, not just switched off.

Questions on this topic

Is LED always cheaper over five years?

On a line running more than about 2,000 hours a year, usually yes. On low-utilization lines the capex gap can dominate for the whole life of the equipment, and a mercury system may be the rational choice.

Can I retrofit an LED head onto an existing mercury conveyor?

Mechanically often yes; optically you must re-check the cure width, the working distance and the ink or adhesive compatibility. Retrofit failures are usually a wavelength or dose mismatch, not a mounting problem.

Does LED output stay constant for its whole rated life?

No. Output declines gradually and the rating is usually quoted to 70% of initial. That is why dose calculations should include margin, and why irradiance should be logged so you can see the decline rather than discover it through scrap.

Send your process details